Operating manual Powder Cup Gun PEM-X1 CG
8   Cleaning and Maintenance
CAUTION
Electrode tip!
Risk of injury and damage to the device.
4 Take care when fitting the electrode holder.
P_01679
1. Unscrew the union nut from gun housing.
2. Remove the union nut with the nozzle system from the gun body.
The nozzle system remains inserted in the union nut.
Note:
If the nozzle system doesn't remain inserted in the union nut, the nozzle system and
union nut must be replaced.
3. The parts can be separated by applying slight pressure to the flat jet nozzle.
4. Attach deflector cone sleeve onto X1 R electrode holder.
6.
8.
P_01690
9.
Order number 2326960 | Edition 10/2022
1.
3.
7.
2.
4.
39