Model
Enclosure
Operating temp. range
Operating humidity range
Withstand voltage
Insulation resistance
Supply port
Detection port
Supply port
Detection port
Lead wire with connector
Centralized lead wire
Weight
Standard
IO-Link type
IO-Link version
Communication speed
Configuration file
Min. cycle time
Process data length
On request data
communication
Data storage function
Event function
Vendor ID
Device ID
∗1: Refer to the relationship between the display value and distance on page
∗2: For ISA3-F type, the range is up to 57, with a hysteresis of 3.
For ISA3-G type, the range is up to 280, with a hysteresis of 20.
For ISA3-H type, the range is up to 480, with a hysteresis of 20.
∗3: The pressure value will be indicated on the sub display.
∗4: When used as a switch output device in SIO mode.
∗5: When OUT2 is set to distance detection.
∗6: When OUT2 is set to pressure detection.
∗7: If the pressure fluctuates around the set value, the hysteresis must be set to a value more than the amount of fluctuation, otherwise
chattering will occur.
∗8: See the figure on page
28
for details of the detection nozzle.
∗9: Applies only to the digital gap checker body excluding the control unit.
∗10: The configuration file can be downloaded from the SMC website, https://www.smcworld.com.
∗11: Any products with tiny scratches, smears, or display colour variation or brightness which does not affect the performance are verified
as conformant products.
ISA3-F
Operation: 0 to 50
o
C, Stored: -20 to 70
Operation/Stored: 35 to 85%RH (No condensation)
1000 VAC or more (in 50/60 Hz) for 1 minute between terminals and housing
2 MΩ or more at 500 VDC, between terminals and housing
φ4 One-touch fitting
M12 lead wire with 4 pin connector, 4 cores φ4 5 m
M12 lead wire with 4 pin connector part, 4 cores, φ4, Insulator O.D.: 1.14 mm
Centralized lead wire part, 2 to 3 stations: 8 cores, φ6, 5 m
4 to 6 stations: 14 cores, φ6, 5 m
Conductor O.D.: 0.50 mm, Insulator O.D.: 1.00 mm (2 to 6 stations common)
113 g (Lead wire not included, One-touch fitting)
CE marked (EMC directive/RoHS directive)
Input Data: 8 byte, Output Data: 0 byte
ISA3-F∗L-∗: 341 (0x0155)
ISA3-G∗L-∗: 342 (0x0156)
ISA3-H∗L-∗: 343 (0x0157)
20
-16-
2
About this product
ISA3-G
IP67 equivalent
∗9
o
C (No condensation or freezing)
Rc1/8
φ6 One-touch fitting
G1/8 (ISO1179-1)
G1/8 (ISO1179-1)
Device
V1.1
COM2 (38.4 kbps)
IODD file
∗10
4.2 ms
Available
Available
Available
131 (0x0083)
for details.
ISA3-H
No.PS※※-OMW0009-C
Need help?
Do you have a question about the ISA3-FCP-4LB-L1 and is the answer not in the manual?
Questions and answers