SMC Networks ISA3-FCP-4LB-L1 Operation Manual page 100

Digital gap checker
Table of Contents

Advertisement

●Product individual parameters (continued)
Index
Sub
Access
index
∗1
dec
hex
1
R/W
1250 0X04E2
2
R/W
1
R/W
2
R/W
3
R/W
1260 0X04EC
4
R/W
5
R/W
6
R/W
7
R/W
1
R/W
1450 0X05AA
2
R/W
1
R/W
2
R/W
3
R/W
1460 0X05B4
4
R/W
5
R/W
6
R/W
7
R/W
1
R/W
1470 0X05BE
2
R/W
Data
Items
Initial value
type
∗2
Output mode
U8
Output type
U8
HYS mode set value
S16
HYS mode hysteresis S16
Wind mode lower
S16
limit set value
Wind mode upper
S16
limit set value
Wind mode hysteresis S16
ON delay time
U16
OFF delay time
U16
Output mode
U8
Output type
U8
HYS mode set value
S16
HYS mode hysteresis S16
Wind mode lower
S16
limit set value
Wind mode upper
S16
limit set value
Wind mode hysteresis S16
Delay time ON
U16
Delay time OFF
U16
Output mode
U8
Output type
U8
-99-
Data
Set value
storage
∗3
0: HYS
1
Y
1: Wind
0: Normal output
0
Y
1: Reverse
output
300
Y
-200 ~ 2200
50
Y
0 ~ 2400
250
Y
-200 ~ 2200
500
Y
-200 ~ 2200
50
Y
0 ~ 1200
100
Y
0 ~ 6000
100
Y
0 ~ 6000
0: HYS
1
Y
1: Wind
0: Normal output
0
Y
1: Reverse
output
300
Y
-200 ~ 2200
50
Y
0 ~ 2400
250
Y
-200 ~ 2200
500
Y
-200 ~ 2200
50
Y
0 ~ 1200
100
Y
0 ~ 6000
100
Y
0 ~ 6000
2: Err
2
Y
3: OFF
0: Normal output
0
Y
1: Reverse
output
4
How to use
Remarks
Setting of OUT1 output mode
Setting of OUT1 output normal and
reserved output
Setting of OUT1 output set value
Setting of OUT1 hysteresis
Setting of OUT1 output set value
(lower limit of window comparator)
Setting of OUT1 output set value
(upper limit of window comparator)
Setting of OUT1 hysteresis
(window comparator hysteresis)
Setting of OUT1 delay time at ON
0.01 s increment (0 to 60 s)
Setting of OUT1 delay time at OFF
0.01 s increment (0 to 60 s)
Setting of OUT2 output mode
Setting of OUT2 output normal and
reversed output
Setting of OUT2 output set value
Setting of OUT2 hysteresis
Setting of OUT2 output set value
(lower limit of window comparator)
Setting of OUT2 output set value
(upper limit of window comparator)
Setting of OUT2 hysteresis
(window comparator hysteresis)
Setting of OUT1 delay time at ON
0.01 s increment (0 to 60 s)
Setting of OUT1 delay time at OFF
0.01 s increment (0 to 60 s)
Selection of output mode when the
OUT2 hardware output is set to
"others"
No.PS※※-OMW0009-C

Advertisement

Table of Contents
loading
Need help?

Need help?