Figure 10-4 Removing the internal fan and the fixing plate
Step 5 Remove the internal fan cable from the main control board.
Figure 10-5 Removing the internal fan cable
Step 6 Remove the internal fan from the fixing plate.
Figure 10-6 Removing the internal fan
Step 7 Install a new internal fan on the fixing plate.
Step 8 Install the fixing plate.
Step 9 Connect and arrange the internal fan cable bundle to the main control board.
Step 10 Install the front cover.
Step 11 Install the air conditioner cables.
Step 12 Install the air duct.
----End