Indirect connection to the Control Board ("Daisy-Chain" Type Wiring)
In this type of installation only one control cable directly connects between the System Controller #1 and the Control Board.
The rest of the System Controllers connect to System Controller #1 in a Daisy-Chain connection.
Refer to the connections and controller settings in the figure shown below.
Matrix Switcher WJ-SX550B
Notes:
• To avoid unstable operation, do not connect more than
4 System Controllers in a daisy-chain connection.
• The response may be poorer in a daisy-chain connec-
tion. To operate multiple System Controllers at the
same time, it is recommended to use a Home Run con-
nection.
• Confirm that the jumper connector (CN13) on the
Control Board is positioned as shown below.
54
Control Board
CONTROL
DATA 1
DATA 2
DATA 3
DATA 4
DATA 5
DATA 6
DATA 7
DATA 8
TEST 1
TEST 2
Daisy-Chain Connections
CN13
DATA
CONTROLLER
IN
OUT
UNIT NO.
1-8
TERM
0
ON
OFF
DATA
CONTROLLER
IN
OUT
UNIT NO.
1-8
TERM
0
ON
OFF
DATA
CONTROLLER
IN
OUT
UNIT NO.
1-8
TERM
0
ON
OFF
DATA
CONTROLLER
IN
OUT
UNIT NO.
1-8
TERM
0
ON
OFF
Termination and Controller Unit Number Setting
Termination
Switch
Controller 1
OFF
Controller 2
OFF
Controller 3
OFF
Controller 4
ON
Note: Do not set "0" or "9" for controller unit numbers.
Controller 1
Controller 2
Controller 3
Controller 4
Controller
Unit Number
1
2
3
4
3