Panasonic WJ-SX550B Operating Instructions Manual page 113

System 500 matrix switcher
Hide thumbs Also See for WJ-SX550B:
Table of Contents

Advertisement

Alarm Control
Alarm Input Selection
The following settings enable or disable alarm inputs from
the camera site or Alarm Board after the Alarm Mode Select
item has been set in the Setup Menu.
1. Select the Alarm in (A5) Menu on the LCD display by
pressing the appropriate Direction button.
A5
Alarm in
Site
F1 F2
2. Press the Function (F1) button to toggle the Camera
Site Alarm on and off.
3. Press the Function (F2) button to toggle the Interface
Alarm (Alarm Board) on and off.
On
Off
Alarm Operation
When an alarm is activated, the ALARM indicator on the
controller blinks.
The indicator keeps blinking until all alarms are cleared by
pressing the ACK RESET button.
To Cancel Alarm (Single Monitor)
1. The alarmed monitor(s) must first be selected.
Refer to the Monitor Selection.
2. Press the ACK RESET button once for alarm acknowl-
edgment.
The LED indicator on the button blinks rapidly.
3. Press the ACK RESET button once again for alarm
reset.
The ALARM indicator goes off, and the LED indicator
on the button goes off.
115
Board
:
Site
Board
:
Site
Board
ALARM LED
ACK
ACK
RESET
RESET
Note: "AL0" or "AL1" is displayed in the upper right
corner of the alarmed monitor.
07 MAY'00 14:23:56
C 01 M16 3rd Floor
Room
To Cancel Alarm (Plural Monitors)
The following function is used to cancel alarm in a lump
when Alarm Mode 1 or 2 is activated.
1. Select the alarmed monitor.
Select Monitor 1 if Alarm Mode 1 is activated, or one of
Monitors 1 - 4 if Alarm Mode 2 is activated.
2. Press the ALT button. The LED indicator on the button
lights.
3. Press the ACK RESET button once for alarm acknowl-
edgment.
The LED indicator on the button blinks rapidly.
4. Press the ACK RESET button once again for alarm
reset.
The LED indicator on the button goes off.
ACK
ALT
RESET
Note: Select one of the monitors that is running the
Group Sequence by activating the Alarm Mode 3,
then follow the steps above to cancel the alarmed
monitors at once.
ALO
306
ACK
RESET
5