FC 300 Operating Instructions

Parameter Lists

Changes during operation
"TRUE" means that the parameter can be changed while the frequency converter is in operation and
"FALSE" means that the it must be stopped before a change can be made.
4-Set-up
'All set-up': the parameters can be set individually in each of the four set-ups, i.e. one
single parameter can have four different data values.
'1 set-up': data value will be the same in all set-ups.
Conversion index
This number refers to a conversion figure used when writing or reading by means of a frequency converter.
Conv. index
100
67
Conv. factor
1
1/60
Data type
Description
2
Integer 8
3
Integer 16
4
Integer 32
5
Unsigned 8
6
Unsigned 16
7
Unsigned 32
9
Visible String
33
Normalized value 2 bytes
35
Bit sequence of 16 boolean variables
54
Time difference w/o date
See the FC 300 Design Guide for further information about data types 33, 35 and 54.
default setting
display text
*
( )
How to Programme
6
5
4
3
1000000
100000
10000
1000
value for use in communication via serial communication port
[ ]
MG.33.A5.02 - VLT is a registered Danfoss trademark
2
1
0
-1
-2
100
10
1
0.1
0.01
-3
-4
-5
-6
0.001
0.0001
0.00001 0.000001
Type
Int8
Int16
Int32
Uint8
Uint16
Uint32
VisStr
N2
V2
TimD
47