FC 300 Operating Instructions
6-** Analog In/Out
Par.
Parameter description
No.
#
6-0* Analog I/O Mode
6-00
Live Zero Timeout Time
6-01
Live Zero Timeout Function
6-1* Analog Input 1
6-10
Terminal 53 Low Voltage
6-11
Terminal 53 High Voltage
6-12
Terminal 53 Low Current
6-13
Terminal 53 High Current
6-14
Terminal 53 Low Ref./Feedb. Value
6-15
Terminal 53 High Ref./Feedb. Value
6-16
Terminal 53 Filter Time Constant
6-2* Analog Input 2
6-20
Terminal 54 Low Voltage
6-21
Terminal 54 High Voltage
6-22
Terminal 54 Low Current
6-23
Terminal 54 High Current
6-24
Terminal 54 Low Ref./Feedb. Value
6-25
Terminal 54 High Ref./Feedb. Value
6-26
Terminal 54 Filter Time Constant
6-3* Analog Input 3
6-30
Terminal X30/11 Low Voltage
6-31
Terminal X30/11 High Voltage
6-34
Term. X30/11 Low Ref./Feedb. Value
6-35
Term. X30/11 High Ref./Feedb. Value
6-36
Term. X30/11 Filter Time Constant
6-4* Analog Input 4
6-40
Terminal X30/12 Low Voltage
6-41
Terminal X30/12 High Voltage
6-44
Term. X30/12 Low Ref./Feedb. Value
6-45
Term. X30/12 High Ref./Feedb. Value
6-46
Term. X30/12 Filter Time Constant
6-5* Analog Output 1
6-50
Terminal 42 Output
6-51
Terminal 42 Output Min Scale
6-52
Terminal 42 Output Max Scale
6-53
Terminal 42 Output Bus Control
6-54
Terminal 42 Output Timeout Preset
6-6* Analog Output 2
6-60
Terminal X30/8 Output
6-61
Terminal X30/8 Min. Scale
6-62
Terminal X30/8 Max. Scale
*
default setting
( )
display text
54
How to Programme
Default value
10 s
[0] Off
0.07 V
10.00 V
0.14 mA
20.00 mA
0.000 ReferenceFeed-
backUnit
ExpressionLimit
0.001 s
0.07 V
10.00 V
0.14 mA
20.00 mA
0.000 ReferenceFeed-
backUnit
ExpressionLimit
0.001 s
0.07 V
10.00 V
0.000 ReferenceFeed-
backUnit
ExpressionLimit
0.001 s
0.07 V
10.00 V
0.000 ReferenceFeed-
backUnit
ExpressionLimit
0.001 s
[0] No operation
0.00 %
100.00 %
0.00 %
0.00 %
[0] No operation
0.00 %
100.00 %
[ ]
value for use in communication via serial communication port
MG.33.A5.02 - VLT is a registered Danfoss trademark
4-set-up
FC 300
Change
series
during
operation
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
1 set-up
TRUE
All set-ups
TRUE
All set-ups
TRUE
All set-ups
TRUE
Conver-
Type
sion index
0
Uint8
-
Uint8
-2
Int16
-2
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-5
Int16
-5
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-2
Int16
-2
Int16
-3
Int32
-3
Int32
-3
Uint16
-
Uint8
-2
Int16
-2
Int16
-2
N2
-2
Uint16
-
Uint8
-2
Int16
-2
Int16