FC 300 Operating Instructions
11-22 kW
No.
96
U
U1
W2
U1
No.
99
PE
All types of three-phase asynchronous standard
motors can be connected to the FC 300. Normally,
small motors are star-connected (230/400 V,
/Y). Large motors are normally delta-connected
(400/690 V,
/Y). Refer to the motor name plate
for correct connection mode and voltage.
NB!:
In motors without phase insulation paper or other insulation reinforcement suitable for operation
with voltage supply (such as a frequency converter), fit an LC filter on the output of the FC 300.
18
How to Install
97
98
Motor voltage 0-100%
V
W
of mains voltage.
3 wires out of motor
V1
W1
6 wires out of motor, Delta-connected
U2
V2
V1
W1
6 wires out of motor, Star-connected
U2, V2, W2 to be interconnected separately
Earth connection
MG.33.A5.02 - VLT is a registered Danfoss trademark