Vi.2 Assistance Service - Galvamet Perfecto Instructions For Installation, Use And Maintenance Manual

Table of Contents

Advertisement

EN
The internal
configurations of the
ER31
TC* and induction are
incongruous
ER35
Internal error at TC*
ER36
Internal error at TC*
Secondary power
ER42
supply not suitable
No communication to
ER47
at least one coupled
LIN
(*) TC = Touch Control (Control Panel)

VI.2 ASSISTANCE SERVICE

Before contacting the Assistance Service it is important to:
-> Check if the problem can be resolved by consulting the error table in the
"Errors/Troubleshooting" paragraph.
-> Switch the appliance off and on again (ON/OFF) to make sure that the problem has been
resolved.
Finally, if after carrying out the above checks the error signals persist, contact the Assistance
Service.
The internal
configuration data of
ER31 is
the induction
displayed
generator is different
continuously
from the configuration
inside the TC*
Shutdown
Shutdown
12V or 5V too high / too low
Damaged LIN cable. No
ER47 is
supply voltage for
displayed
coupled LIN.
continuously
Faulty coupled LIN.
49 
Download the configuration.
If the error is still present,
replace the TC*. If the error is
still present, replace the
induction generator.
Replace TC*
-
Replace TC*
-
Check and replace the LIN
wiring.
Check the supply voltage.
Replace coupled LIN.