Dynamic Form: Repeat
Purpose
Repeats (duplicates) an entire form within a boilerplate dynamic
form.
Format
(cc) R formdata (cc)Z(cc)-
(cc)
R
formdata
(cc)Z(cc)-
Comments
The Dynamic Form: Repeat command is supplied as the first
input of the data parameter within the Dynamic Form command.
Do not use this command with the Dynamic Form: Copy Fields
command (page 69).
The LF and FF commands (as previously described on page 66)
have an additional meaning when used with Dynamic Form:
Repeat commands.
When the data is supplied, the first parameter becomes a four-
digit repeat number field. For example, 0003 before the first
dynamic data byte specifies three repeated forms with the data.
The repeat number field must be supplied with each set of data
when the Dynamic Form: Repeat command is used. If only one
copy of the form is required, enter 0001 as the repeat number.
Dynamic Form Commands
Represents the Special Function Control Code
(SFCC). Enter the specific SFCC for your VGL
configuration.
Specifies the Dynamic Form: Repeat command.
Enter R to repeat the boilerplate form.
Represents the dynamic form data. Any text,
graphics command sequences, or dynamic form
field length, are entered as part of the data.
This is not the dynamic data for the variable fields;
this data represents all information required for the
boilerplate form to be repeated. The number of
copies of the form is specified as part of the
dynamic data sequence after the dynamic form is
processed.
Terminates the repeat sequence. Enter the SFCC
for your VGL configuration immediately followed by
Z, another SFCC, and - or another valid graphics
command mnemonic to terminate the Dynamic
Form Copy Fields sequence.
71