UPCSHIP

The UPCSHIP bar code structure is shown in Figure 26 and described on the
following pages.
STARTING
POSITION
QUIET START
DATA FIELD
ZONE
CODE
LOWER GUARD BAND
OPTIONAL READABLE DATA FIELD
Figure 26. UPCSHIP Structure
Quiet Zone
Both ends of the bar code structure have blank quiet zones. The quiet zones
should be at least 0.25 inches wide and completely blank to ensure accurate
reading of the start/stop codes and to prevent adjacent bar codes from
overlapping. You are responsible for providing sufficient space on the form for
the quiet zones.
Start/Stop Codes
Unique start and stop codes permit bidirectional scanning. Both start and stop
codes contain bars and spaces. They are automatically produced.
Data Field
The bar code symbol uses a series of wide and narrow bars and spaces to
represent numeric characters. The structure is 2 wide elements (bars or
spaces) and 3 narrow elements.
STARTING
POSITION
OPTIONAL
READABLE
OPTIONAL
CHECK DIGIT
STOP
QUIET
CODE
ZONE
HEIGHT
UPCSHIP
HEIGHT
QUIET
ZONE
START
CODE
DATA
DATA
FIELD
FIELD
OPTIONAL
CHECK
DIGIT
STOP
LOWER
CODE
GUARD
BAND
QUIET
ZONE