JAI GO-5000M-PGE User Manual page 60

Cmos digital progressive scan monochrome and monochrome uv camera with gige interface
Hide thumbs Also See for GO-5000M-PGE:
Table of Contents

Advertisement

GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Trigger Activation
This command can select how to activate the trigger.
Rising edge: At the rising edge of the pulse, the trigger is activated.
l
Falling edge: At the falling edge of the pulse, the trigger is activated.
l
Level High: During the high level of trigger, the accumulation is activated
l
Level Low: During the low level of trigger, the accumulation is activated
l
If Exposure Mode is set to Trigger Width, Level High or Level Low must be used.
Camera Settings
Trigger
Trigger
Selector
Mode
On
Frame
On
Start
On
✓ : Supported
Trigger Overlap
On this camera, the trigger overlap function is fixed to Readout.
Readout: The trigger pulse can be accepted during the sensor readout.
l
Trigger
Exposure
Option
Mode
Timed
Off
Timed
RCT
Trigger
Off
Width
JAI Custom Trigger
Mode Name
EPS Trigger
RCT Trigger
PWC Trigger
- 60 -
Main Functions
Trigger Activation Setting
Rising
Falling
Level
Edge
Edge
High
Level
Low