GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Trigger Selector
Selects the trigger operation. On this camera, the following trigger operation can be selected as the
trigger.
Trigger Selector Item
Frame Start
Acquisition Start
Acquisition End
Acquisition Transfer Start
Each trigger has the following setting parameters, and those parameters are configured on each
trigger selector item.
Setting parameters: Trigger Mode, Trigger Software, Trigger Source, Trigger Activation
Trigger Mode
Select either free-running operation or external trigger operation.
OFF: Free-running operation
l
ON: External trigger operation (Initiate the trigger operation selected in Trigger selector)
l
Trigger Source
The following signals can be used as the trigger source signal.
Trigger Source
Item
Low
Connect LOW level signal to the selected trigger operation (Default setting)
High
Connect HIGH level signal to the selected trigger operation
Connect Soft Trigger signal to the selected trigger operation. Trigger can be input manually
Soft Trigger
by the execution of the software trigger. Trigger software is available on each trigger
source.
PulseGenerator0 Connect Pulse generator 0 signal to the selected trigger operation
Line 5 - OPT IN 1 Connect OPT IN 1 signal to the selected trigger operation
NAND 0 Out
Connect NAND 0 OUT signal to the selected trigger operation
NAND 1 Out
Connect NAND1 OUT signal to the selected trigger operation
User output 0
Connect User output 0 signal to the selected trigger operation
User output 1
Connect User output 1 signal to the selected trigger operation
Action 1
Connect Action 1 OUT signal to the selected trigger operation
Action 2
Connect Action 2 OUT signal to the selected trigger operation
Frame Start Trigger operation
Acquisition Start Trigger operation
Acquisition End Trigger operation
Transfer Trigger operation (for delayed readout)