1.
Install the expansion card
2. If applicable, connect the cables to one or more expansion cards.
3. Follow the procedure listed in
4. Confirm that the battery is operating properly, by performing the following steps:
a. Enter the System Setup, while booting, by pressing F2.
b. Enter the correct time and date in the System Setup Time and Date fields.
c. Exit the System Setup.
d. To test the newly installed battery, remove the system from the enclosure for at least an hour.
e. Reinstall the system into the enclosure after an hour.
f. Enter the System Setup and if the time and date are still incorrect, see

Optional internal USB card

NOTE:
To locate the internal USB port on the system board, see the

Removing the internal USB card

Prerequisites
CAUTION:
To avoid interference with other components in the server, the maximum permissible dimensions of
the USB memory key are 15.9 mm wide x 57.15 mm long x 7.9 mm high.
1. Follow the safety guidelines listed in the
2. Follow the procedure listed in the
3.
Remove the expansion card
Steps
1. Holding the blue tag, lift the internal USB card to disconnect from the connector on the system board.
2. Remove the USB memory key from the internal USB card.
Figure 130. Removing the internal USB card
158
Installing and removing system components
risers.
After working inside your
Safety
instructions.
Before working inside your
risers.
system.
Getting help
System board jumpers and connectors
system.
section.
section.

Advertisement

Table of Contents
loading

This manual is also suitable for:

E102s

Table of Contents