TROUBLESHOOTING
Symptom
Tumbler does not turn
Probable Cause
Drive Belts
Drive Motor
Door Switch
Electronic Control
Motor Run Relay
Suggested
Remedy
Check both drive belts.
Replace if failed.
Check capacitor and
motor. Replace if failed
Check for door closed
L.E.D on control
board. Check door
switch contacts and
adjustment. Adjust or
replace door switch.
Is electronic control
closing motor relay to
power drive motor?
Check for motor light
on electronic control.
If no light and time
counting down, change
control. If light is on,
check for proper voltage
and wiring to motor
relay in rear control
compartment.
Test for proper voltage
to run relay coil, test
output voltage of relay
when contacts engaged,
if no voltage replace
relay.
Part # 8533-120-001 9/21