Dexter Laundry T-750 C4 Installation And Parts & Service Manual page 148

Commercial vended stack washer dryer
Table of Contents

Advertisement

Troubleshooting Machine Fault Errors Continued
Fault
Description
SLOW
Drain Error
DRAIN
ERROR
SPIN
Stop Error
STOP
ERROR
DRIVE
Washer Size/ VFD
ERROR
Size Mismatch
1
148
Part # 8533-120-001 9/21
Customer Action
Condition
This error is when an empty water level is not
reach within 7 minutes.
Delay
Immediate
Action
The washer cycle will continue. Do not spin
the tumbler with out reaching an empty water
level. If empty water level is not reached,
agitate during the normal spin time.
Solution
Check VFD fault light before turning off power.
Check to ensure the drain valve is operating
properly (slow drain has potential to cause this
code). Check to ensure the pressure switch
tube is clear of any blockage, and the pressure
switch is operating properly. Check the
pressure switch harness.
Condition
This error is when the washer does not stop
spinning within 150 seconds after receiving the
command.
Delay
Immediate
Action
Keep the door locked until the machine has
stopped moving and then unlock the door.
Solution
Check VFD fault light before turning off power.
Inspect the braking resistors and measure
the resistance. Check connecting wiring from
braking resistor to the drive mounted in the top
of the washer. Reset the drive and try again.
Possibly incorrectly programmed drive.
Condition
This error is when the drive size does not
match the washer size.
Delay
Immediate. (After the size jumper configuration
is read). Washer size/type inputs are read
only at power up, before starting a cycle, once
every 24 hours and in factory test mode
Action
Stop the machine and clear the cycle. Keep
the door locked until the machine has stopped
moving and then unlock the door
Solution
Check VFD fault light before turning off power.
If the controller was installed in a different
size machine before being installed in this
machine, a problem can occur. If someone has
been doing repairs on the washer, check for
the correct size drive. It can also be caused by
pressure switch harness. Check to ensure the
correct harness in installed. The control can be
reset by holding program button on controller
during startup (soft reset). Check orange wire
at Molex connector on controller coming from
pressure switch or replace pressure switch
harness.