Dexter Laundry T-750 C4 Installation And Parts & Service Manual page 76

Commercial vended stack washer dryer
Table of Contents

Advertisement

Error Codes
Symptom
PCB ERROR2
COMM ERROR1
COMM ERROR2
COMM ERROR7
FUSE ERROR
CRC ERROR
76
Part # 8533-120-001 9/21
Probable Cause
Analog / Digital Error
Communication Bus
Error
No Dryer Model Selected This error occurs when a pin combination
Communication Bus
Error
Programming Error
Firmware Corrupted
Suggested Remedy
Power machine down and try to reset
control. Verify voltage to the control
board. Check ground to board. Replace
control board if error can not be cleared
Power machine down and try to reset
control. Verify voltage to the control
board. Check ground to board. Replace
control board if error can not be cleared
on the model selection header is used
that does not have a model designated
for it. Check connector marked Jumpers
on the control board.
If a state-of-health message reply is not
seen by the master microprocessor from
the UC3 microprocessor after 10 minutes,
the master will reset the UC3 and restart
the 10 minute timer. Again, after 10
minutes, if a state-of-health message is
not received by the master, it will reset
the UC3 a second time. After 10 minutes,
the master will reset the UC3 a final time
and post a COMM ERROR 7. Note: When
the master resets the UC3, the control
will disconnect from the network. If the
first reset is not successful, the control
will not be able to reconnect to the
network, USB or card reader functions.
This error occurs when the fuse settings
have not been set correctly during
factory programming, Replace Control
This error occurs the dryer control
firmware fails a CRC check. Replace
Control

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-450

Table of Contents