Prices Option:
This option allows the user to set values for coin acceptor inputs and to set the vend price. It also allows
the user to return the values to factory defaults. "RIGHT COIN" and "LEFT COIN" are the two possible
inputs from coin acceptors.
"SET VEND" is the actual Base Vend Price (or Vend Price A) that is shown on the control display.
After changing prices using the "UP" or "DOWN" buttons, the "ENTER" button must be pressed again for
the control to store the changes that have been made.
To reset either the coin acceptor inputs or the vend price to factory default, press "ENTER" when the "DE-
FAULT" prompt is shown. Press "ENTER" again when the "RESET" prompt is shown to confirm the action.
Figure 5, shown below, shows the sub menu options for Prices:
PRICES
COIN_VALUE
VEND_PRICE
RIGHT_COIN
LEFT_COIN
DEFAULT
SET_VEND
DEFAULT
00.01-99.99
(00.01 increments)
00.01-99.99
(00.01 increments)
RESET
FREE - 00.01-99.99
(00.01 increments)
RESET
Part # 8533-120-001 9/21