Dexter Laundry T-750 C4 Installation And Parts & Service Manual page 147

Commercial vended stack washer dryer
Table of Contents

Advertisement

Troubleshooting Machine Fault Errors Continued
Fault
Description
COMM
Communication
ERROR 7
Bus Error
COMM
VFD
ERROR 8
Communication
Fault
PCB
Controller Internal
ERROR1
Fault
PCB
Controller Internal
ERROR 2
Fault
Customer Action
Condition
If a state-of-health message reply is not seen by the
master microprocessor from the UC3 microprocessor
after 10 minutes, the master will reset the UC3 and
restart the 10 minute timer. Again, after 10 minutes,
if a state-of-health message is not received by the
master, it will reset the UC3 a second time. After 10
minutes, the master will reset the UC3 a final time
and post a COMM ERROR 7.
NOTE: When the master resets the UC3, the
control will disconnect from the network. If the first
reset is not successful, the control will not be able
to reconnect to the network, USB or card reader
functions.
Delay
3 cycles of 10 minutes (see above)
Action
Stop the machine and clear the cycle. Keep the
door locked until the machine has stopped moving
and then unlock the door.
Solution
The washer will not restart until the power is
removed and re-applied.
Condition
This error is caused when the VFD reports a
frequency value that is out of range
Delay
Delay time is 35 seconds
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and
then unlock the door.
Solution
The washer will not restart until the power is
removed and re-applied.
Condition
This error is an internal failure of the washer
controller electronics.
Delay
Immediate
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and
then unlock the door.
Solution
Check VFD fault light before turning off power. Try a
soft reset of the controller with the white button. If
problem. Replace PCB controller.
Condition
This error is an internal failure of the washer
controller related to inputs being matched between
the master and slave micros
Delay
Immediate
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and
then unlock the door.
Solution
The washer will not restart until the power is
removed and re-applied.
Part # 8533-120-001 9/21
147

Advertisement

Table of Contents
loading

This manual is also suitable for:

T-450