Troubleshooting Machine Fault Errors Continued
Fault
Description
DRIVE
VFD
OH
Overheat
Fault
DRIVE OL VFD
Overload
Fault
DRIVE
VFD Ground
GFI
Fault
DRIVE LV
VFD Low
Voltage
DRIVE IF
VFD Internal
Fault
150
Part # 8533-120-001 9/21
Customer Action
This error is over-heating on the VF drive
Condition
Delay
Occurs following the "DELAY" error (see
corresponding detail)
Action
Stop the machine and clear the cycle. Keep
the door locked until the machine has stopped
moving and then unlock the door.
Solution
The washer will not restart until the power is
removed and re-applied.
Condition
This error is overload on the VF drive
Delay
Occurs following the "DELAY" error (see
corresponding detail)
Action
"DRIVE OL"
The washer will not restart until the power is
Solution
removed and re-applied.
Condition
This error is a ground fault interruption on the VF
drive
Delay
Occurs following the "DELAY" error (see
corresponding detail)
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and
then unlock the door.
Solution
The washer will not restart until the power is removed
and re-applied.
Condition
This error is low voltage on the VF drive
Delay
Occurs following the "DELAY" error (see
corresponding detail)
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and
then unlock the door.
Solution
The washer will not restart until the power is removed
and re-applied.
Condition
This error is an internal VF drive error
Delay
Occurs following the "DELAY" error (see
corresponding detail)
Action
Stop the machine and clear the cycle. Keep the door
locked until the machine has stopped moving and
then unlock the door.
Solution
The washer will not restart until the power is removed
and re-applied.