The dryer can be set to reverse at different intervals dependent on owner's preference.
The style of operation is determined by the location of the BROWN jumper wire located
in the rear control box, on the frequency drive. (See image for jumper location)
V Series Washer
Max Spin
Model
T-300, T-400,
T-600, T-900,
Style
Dryer
T-1200
Operation
T-350, T-450,
1
NON-REV.
T-750
2
3
4
T-950, T-1450
5
REVERSING OPTIONS
Jumper Terminal Locations on Variable Frequency Drive (VFD)
MI1 MI2 MI3 MI4 MI5 MI6
Speed
60 G
80 G
FWD
100 G
(sec)
60 G
100 G
YES
140 G
REV.
30
200 G
REV.
60
100 G
REV.
90
140 G
REMOVE Brown Jumper between MI5/M01
REV.
120
200 G
Default Setting (With Factory Installed Brown Jumper)
DCM
DCM
(Left)
(Right) 24V ACM AVI ACI 10V M01
X
X
REV
Default Setting (No Jumper Required)
(sec)
X
X
NO
X
X
30
Default Setting (No Jumper Required)
60
90
120
X
X
Jumper Locations
Pos (1)
Pos (2)
X
X
DCM
MCM
DCM
MI2
DCM
MI4
X
X
DCM
MI5
DCM
MI6
Part # 8533-120-001 9/21