Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
2. Divide the scan area into three parts and set a preset every 120°. The black numbers are presets,
and the red numbers are scan areas.
3. Set the presets according to the sequence of patrol path: 1->2->3->1->4->5->6->4.
Note
When set the presets, you should adjust the zoom ratio to view the image of both optical
●
channel and thermal channel clearly.
The recommended zoom ratio of optical channel and patrol speed shows in the table below.
●
Figure 4-2 Set the Presets for fire detection