To Remove The Complete Burner Module, Pipes And Pilot; To Remove The Gas Flow Rate Controller - Valor BRAVA 348 Installer And Owner Manual

Radiant / convector
Table of Contents

Advertisement

INSTALLER GUIDE
7. Carefully slide the burner module to the right to free it from the right side of the
radiant box (See figure 17).

12.7 To remove the complete burner module, pipes and pilot.

1. Remove the fascia as in section 12.2.
2. Isolate the gas supply.
3. Remove the battery from the electronic ignition unit.
4. Support the inlet 'T' connector to avoid straining the pipework and disconnect the
appliance.
5. Disconnect the slider control by removing the knurled screw from the connector
arm. Rotate the control pivot bracket fully
anticlockwise.
6. Make a note of where the igniter unit
leads are located, then remove the two
microswitch leads and ignition lead from
the igniter unit; pull the tags and not the
leads as this may cause damage.
7. Unscrew and remove the three screws
from the rear of the assembly (See figure
18).
8. Detach the left end of the burner
module from the radiant box by removing
one screw and a wing nut (See figure
17).
9. Lift the slider arm and carefully slide
Figure 18.
the burner module to the right to free it
from the right side of the radiant box (See figure 17).
10. Replace in the reverse order.
12.8 To remove the gas flow rate
controller.
The gas flow controller and pivot
bracket are identified in figure 19.
1. Remove the complete burner
module, pipes and pilot as in section
12.7.
2. When working on the module,
ensure that the work surface is suitably
protected. This will avoid damage to
the work surface.
3. Remove the nut and washer
securing the control pivot bracket to
the controller at the front. Support the
Figure 19.
pivot bracket while removing the nut to
Page 29
©
GDC Group Ltd. 2011

Advertisement