EVERY 3000 HOURS

• Also,
observe
the
protection
regulations
antifreeze.
Always use a 50/50 mix of antifreeze and clean soft
water in Kubota engines.
Consult your local Kubota Dealer concerning coolant
for extreme conditions.
1. Coolant comes in several types. Use ethylene
glycol (EG) type for this engine.
2. Before employing the 50/50 mix, fill the radiator with
fresh water and empty it again. Repeat this
procedure 2 or 3 times to clean up the inside.
3. Mixing the coolant
Premix 50 % antifreeze with 50 % clean soft water.
When mixing, stir it up well, and then fill into the
radiator.
4. The procedure for the mixing of water and
antifreeze differs according to the make of the
antifreeze and the ambient temperature. Refer to
SAE J1034 standard, more specifically also to SAE
J814c.
IMPORTANT :
• When mixing the antifreeze with water, the
antifreeze mixing ratio is 50 %.
Freezing point
Vol% An-
tifreeze
50
-37
5
*
At 1.013 × 10
Pa (760 mmHg) pressure (atmospheric).
A higher boiling point is obtained by using a
radiator
pressure
development of pressure within the cooling
system.
5. Adding the coolant
a. Add only water if the coolant level reduces in
the cooling system by evaporation.
b. If there is a mixture leak, add the antifreeze of
the same manufacturer and type in a 50/50
mixing ratio.
ZD1611LF,ZD1611RLF,ZD1611RL
relevant
environmental
when
disposing
*
Boiling point
-34
108
226
cap
which
permits
IMPORTANT :
• Never mix different brands of coolant.
(Different brands may have different
additive components, and the engine
may fail to perform as specified.)
6. When the coolant is mixed, do not use any radiator
cleaning
agent.
anticorrosive agent. If mixed with the cleaning
agent, sludge may build up, adversely affecting the
engine parts.
7. Kubota's genuine long-life coolant has a service life
of 2 years. Change the coolant every 2000 hours or
every 2 years whichever comes faster.
of
NOTE :
• The
above
standards that necessitate a minimum glycol
content in the concentrated antifreeze.
EVERY 3000 HOURS

1. Checking injection pump

Consult your local Kubota Dealer for this service.

2. Checking turbo charger

Consult your local Kubota Dealer for this service.

3. Checking EGR system

Consult your local Kubota Dealer for this service.

4. Checking supply pump

Consult your local Kubota Dealer for this service.
EVERY 3000 HOURS TO 6000
HOURS

1. Cleaning DPF muffler

Removal of ash
The longer the DPF operates, the more ash (burnt
residue) is collected in the filter. Too much ash build-up
adversely affects the DPF performance.
• Ash cleaning notification
the
After every 3000 hours to 6000 hours on the hour
meter, the master system warning indicator lights
up and when the code shown in the following is
displayed on the liquid crystal display, DPF needs
to be cleaned.
The clean-up intervals depend on the engine's
operating conditions and other factors.
 MAINTENANCE
The
antifreeze
contains
data
represent
industry
an
103