Return to TOC
Motor Temperature Input
The traction motor's temperature sensor input measures the resistance of the connected sensor. The
controller supports KTY8x, and PT1000 temperature sensors. A parameter-VCL sensor configuration
profile allows the usage of custom solutions, with a maximum source current of less than 2 mA. The
controller is unable to use low resistance sensors, such as the PT100.
In all cases, connect the sensor's ground/negative lead to the controller's I/O ground.
Table 17 Motor Temperature Sensor Specifications
1
LOS Mode: 100°C in case of sensor failure.
±5°C full range temperature accuracy.
2
3
±15°C for 24V F2-A, ±5°C for other models.
When using custom sensors, note that maximum resistance measurement range supported in default configuration is 4k Ohms.
4
Temperature sense accuracy does not apply to custom sensors.
Custom sensor setup is via VCL. Consult Curtis.
2 — INSTALLATION AND WIRING
Curtis AC F2-A, F4-A, F6-A Motor Controllers – FOS 4.5 – April 2022
5
Sin/Cos Max
4.5
4
3.5
3
2.5
2
V
off
1.5
1
0.5
0
0
50
Signal
Pin
–40 – 250°C
Motor Temp
8
VCL Functions
80°C in case of disabled sensor.
Definitions
100
150
200
Electrical Degree
Temperature
• Type
4
1
• KTY83-122
2
• KTY84-130
2
• KTY84-150
2
• PT1000
3
V
Amp
V
PP
Sin/Cos Min
250
300
350
Resistance
Measurement Range
250 – 5k Ω
± 20 Ω @ ≤ 2k Ω
VCL Monitor Variables
Motor_Temperature
MotorTempCutback
Analog_Input_Volts_2
MotorTemp_Sensor1_Resistance
MotorTemp_Sensor2_Resistance
400
Accuracy
pg. 31