PARAMETER
Control Mode Select
Control_Mode_Select
0x3080 0x00
Use speed and torque modes for either traction or pump motors. The speed modes are typically for
material handling vehicle applications. Torque mode is for on-road vehicle applications.
Note: Tune using the specific control mode, speed or torque, but not both. For example, if adjusting a
torque control parameter while Speed Mode or Speed Mode Express has been selected as the tuning
mode, the (CIT/1313) programmer will show the new setting but it will have no effect.
PMDC open loop voltage/speed control
This is the Motor Technology parameter (0x3534) value 6, PMDC (permanent magnet DC motors).
The diagram illustrates two permanent magnet DC motors connected to the three AC phases UVW.
Consult Curtis and the PMDC supplement manual before proceeding with this control mode.
4 — PROGRAMMABLE PARAMETERS
Curtis AC F2-A, F4-A, F6-A Motor Controllers – FOS 4.5 – April 2022
CONTROL MODE SELECT
ALLOWABLE RANGE
DEFAULT
Enumerated
0
0 – 7
DESCRIPTION
This parameter determines which motor control method will be in
effect when controlling the motor:

0 = Speed Mode Express

1 = Speed Mode

2 = Torque Mode
Consult Curtis for these Control Modes:
3 = Direct Torque Mode (Nm)
1
4 = Simplified Torque Mode
2
5 = Steering Mode
3
6 = PMDC open loop voltage/speed control
7 = Servo Speed Mode