Register Address
Parameter
Description
Hex
Input 2
89F
Transmitter
Characterization
Decimal
ATTENTION: Changing the Input Type will result in the loss
of Field Calibration values and will restore the Factory
Calibration values.
2207
Chapter 11 - Modbus RTU Function Codes 20&21
Data
Access
Type
INT
R/W
Data Range or
Enumerated
Selection
26 = 0-20 mA
27 = 4-20 mA
28 = 0-10 mV
29 = 0-50 mV
30 = 0-100 mV
31 = 1-5 Vdc
32 = 0-5 Vdc
33 = 0-10 Vdc
34 = Slidewire
0 = TC B
1 = TC E High
2 = TC E Low
3 = TC J High
4 = TC J Mid
5 = TC J Low
6 = TC K High
7 = TC K Mid
8 = TC K Low
9 = TC M High
10 = TC M Low
11 = TC N High
358