Honeywell UDC2800 Product Manual page 343

Universal digital controller
Hide thumbs Also See for UDC2800:
Table of Contents

Advertisement

Chapter 11 - Modbus RTU Function Codes 20&21
Parameter Description
Ramp Unit
Recycles
Segment 1 Ramp
Segment 2 SP
Segment 2 Time
Segment 3 Ramp
Segment 4 SP
Segment 4 Time
Segment 5 Ramp
Segment 6 SP
Segment 6 Time
Segment 7 Ramp
343
Register Address Data
Type
Hex
Decimal
854
2132
INT
855
2133
INT
83
131
FP
84
132
FP
85
133
FP
86
134
FP
87
135
FP
88
136
FP
89
137
FP
8A
138
FP
8B
139
FP
8C
140
FP
Data Range or
Access
Enumerated
Selection
2 = Soak 4
3 = Soak 2
0 = Time Hrs:Mins
R/W
1 = Rate EU/Mins
2 = Rate EU/Hrs
R/W
0 to 100
99.59 (0-99 Hrs:0
R/W
-59 Min)  or
0 to 999
(Degrees/Minute)
Within Setpoint
R/W
Limits
99.59 (0-99 Hrs:0
R/W
-59 Min)
99.59 (0-99 Hrs:0
R/W
-59 Min)  or
0 to 999
(Degrees/Minute)
Within Setpoint
R/W
Limits
R/W
99.59 (0-99 Hrs:0
-59 Min)
99.59 (0-99 Hrs:0
R/W
-59 Min)  or
0 to 999
(Degrees/Minute)
Within Setpoint
R/W
Limits
99.59 (0-99 Hrs:0
R/W
-59 Min)
R/W
99.59 (0-99 Hrs:0
-59 Min)  or
0 to 999
(Degrees/Minute)

Hide quick links: