Start-up / shut-down

5. Start-up / shut-down
Abstract
This section describes how to start up and shut down the pump. You get to know which inspections contribute to
failure-free operation and increased life of the pump.

5.1 Start-up

5.1.1 Check application conditions

5.1.2 Starting up the pump

5.1.3 Functional check of the mechanical
seal
BA.017.BYY.001.01.10.GB
Check the application conditions of the pump in this way:
1. Compare the data of the following documents with the
2. Make sure that the pump will operate under the men-
Start up the pump in this way:
1. Check tightness of connection.
2. Make sure that all safety equipment is installed.
3. Make sure that all electrical connections are correct.
4. Open the check valves in the system.
5. Fill the pump together with the system.
6. Vent the pump and system.
7. Fully open the check valve on the suction side.
8. Close the check valve on the discharge side.
9. Start the pump.
10. Slowly open the check valve on discharge side.
Ca ution
Overheating and pressure overloading!
!
If delivery head does not rise after the pump has been
turned on:
1. Switch off the pump.
2. Vent the pump (system) again.
3. Repeat steps 7., page 25 to 10., page 25.
Check the function of the mechanical seal in this way:
1. Watch the pump and check the mechanical seal for flaw-
If liquid pumped or flushing liquid leak:
1. Switch off the pump.
2. Renew the mechanical seal.
provided application condition of the pump:
- purchasing documents (confirmation of the order)
- nameplate
- operating manual.
tioned conditions only. This conditions apply to (e. g.)
pressure, temperature, liquid pumped.
Damage to property.
Never operate the pump against a closed shut-off device.
Operation with a shut-off device must on no account con-
tinue for longer than 30 seconds.
less functioning (leak test).
An intact mechanical seal works virtually without leakage.
Observe section 6.1, page 27
25