Technical Indication - Chziri ZVF200-M User Manual

Vector inverter
Table of Contents

Advertisement

Chapter 2 Introduction to the Product
Inverter Models
Input Voltage
(ZVF200-M)
(V)
220
ZVF200-M0055T2
380
ZVF200-M0007T4
380
ZVF200-M0015T4
380
ZVF200-M0022T4
ZVF200-M0037T4
380
ZVF200-M0055T4
380
ZVF200-M0075T4
380

2.6 Technical Indication

Item
Rated voltage
Single phase/Three phase 220VAC . Three phase
frequency
380V.50HZ/60HZ
Allowable Voltage
Voltage fluctuate range: 220V:180V~264V ;380V:342~528V.
range
Voltage unbalance rate:<3%. Frequency fluctuation:
Rated voltage
0~ three phase input AC voltage
Frequency
0.1~400HZ.
SPWM (sinusoidal Pulse Width modulation)
Modulation mode
Control mode
V/F control & sensorless vector control
Frequency
Digital setting :0.1HZ. Analog setting :Max.
Frequency x0.1%.
resolution
Overload capacity
150% of rated current for 1 minute
Including the auto-torque .Auto-slip compensation .
Torque
Start torque can be 150% at 5.0HZ.
Characteristic
0.1~600 seconds ( 2 independment setting for
Acel/Decel Time
Accel/Decel time )
-12-
Rated output
Adaptive Motor
current (A)
Power (KW)
25.0
5.5
3.0
0.75
4.0
1.5
5.0
2.2
8.5
3.7
13
5.5
18
7.5
Item Description
5%
Chapter 2 Introduction to the Product
Item
V/F pattern
Adjustable V/F Pattern
Operation frequency 0~50HZ . Output 0~100 %
DC Breaking
rated current .
Starting time 0~5 seconds . Stop time 0-25 seconds
Carrier frequency
1.0~15.0KHZ
Stall prevention level
20%~200% setting of rated current of inverter
Frequency setting
according to the motor load characteristic
Keypad .External terminal control . COM Serial control
Command
Keypad potentiometer setting . Operation panel
Frequency setting
setting . external Terminal UP/DOWN setting .
Analog signal setting . 485 COM Setting .
Multi-function
0-10VDC singal . Output frequency . current .output .
analog output
Programmable relay . open collector output . Fault
Output signal
signal output .
AVR .Over voltage . Over-current stall prevention .
3-Groups fault records . Reverse inhibition .
Momentary Power loss restart . DC braking .
Auto torque& slip compensation . acceleration/
deceleration. S- curve .auto tuning . adjustable
Other Function
carrier frequency. Frequency limits . Parameter lock
/reset. Vector control . PID control . Counter .remote
control .MODBUS communication . Abnormal reset ,
Abnormal restart . energy saving running . sleep/
revival function . 1st/2nd frequency source selection .
can show the inverter running status. monitor
LED Display
parameters. function parameters .error and ect.
braking assembly,remote keypad and connection
Optional parts selection
cable and soon.
-13-
Item Description

Advertisement

Table of Contents
loading

Table of Contents