4.1 Operation Panel and Description

4.1.1 Operation Panel
MODE Key
program/function mode
ENTER/STORE Key
Panel Potentiometer
Fig.4-1 ZR06 Operation Panel Description
Model: ZVF200-M0004S2 M0022S2
ZVF200-M0004T2 M0055T2
ZVF200-M0007T4 M0075T4
-26-
LED display
display frequency,
current, parameters,
error and etc.
LED Indicates
Lamp lights during RUN,
STOP,FWD & REV
operation.
RUN Key
STOP/RESET Key
UP and DOWN Key
Chapter 4 Operation panel and Operation
4.1.2 Function Description on Keys
Run Key. When the run command selected bey the keypad control
(P01=00).Press this key and the inverter start running .
STOP/RESET key. when the run command is selected by the keypad
control .(P01=00). The inverter is under normal running. Press th is key
to stop running.When the inverter is in the state of failure alarm.Press
this key remove the fault .and return to the normal status .
Program/Function mode key Press this key to displays the AC drive
status, setting fr equency .o utput curr en t . FW D/ RE V. pa ram ete rs
settings and so on.
E nte r/S tor e key. Press this key to confirm the current status of the inverter
or save the current parameter value.
Up key. Press this key, the data or parameter code will go up. Press and
hold it, the modifying speed upward will rise.
Down key. Press this key, the data or parameter code will go down. Press
and hold it, the modifying speed downward will rise.