Chziri ZVF200-M User Manual page 19

Vector inverter
Table of Contents

Advertisement

Table 5-1 Trial Operation Steps
Operation
Order
After energized, the inverter is in the state
Switch on, inverter
of readiness and LED displays F50.00Hz.
1
energized.
the built-in cooling fan begin to work.
Set the frequency to F5.00Hz. This step can
Press
/
till LED
be left out if the displayed frequency is
2
displays F5.00Hz.
already F5.00Hz when energized.
M o t o r b e g i n s r u n n i n g , t h e f r e q u e n c y
rise from H0.00Hz to H5.00Hz, under the
3
Press RUN .
frequency monitor
Keep a close eye on the
If there is any anomaly or tripping, stop
following points:
running immediately and cut off the power
if there is any abnormal
supply.
vibration or noise when the
Please refer to Chapter 7, find the trouble
motor runs.
causes, then proceed trial operation again
if there is any tripping or
4
other abnormality of the
after troubleshooting.
inverter.
If the motor runs in the wrong direction,
If the motor runs in the
change arbitrary two-phase connection of
correct direction.
the output terminal U, V or W.
if the value for rotation
Go to the next step if everything is normal.
speed and frequency is correct.
The motor accelerates rotating and the
Press
continuously till
displayed frequency rises from H5.00Hz to
5
LED displays F50.00Hz.
H50.00Hz. Go to the next step if everything
is normal.
The motor decelerates rotating and the
Press
continuously till
displayed frequency falls from H50.00Hz to
6
LED displays F0.00Hz.
H0.00 Hz. Go to the next step if everything
is normal.
The inverter stops outputting, the motor
stops running and the trial operation ends.
7
Press STOP .
If everything is normal, please repeat the
operation for several times.
-32-
Chapter 5 Inverter Use
Description
5.1.3 Cautions for Operation
All the inverter functions are determined by set parameters. The
parameters of inverter ZVF200 series consist of the function codes
P00~P157, see the detail in Chapter 6 of this manual. The displayed
parameter value of each function code is the factory default value of the
inverter before EX factory, which can be modified by the user according
to his needs. It is noteworthy that a user shall change the relative function
parameters when he amends a parameter because some of the parameters
are inter-related . It is not recommended to modify the set parameter value
if there is no special requirement, for the factory default setting has been
done properly. Otherwise, this may cause damage to the inverter or
equipment due to error parameter.
In case there is an error alternation of the parameter, please initialize
the parameter with reference to the operation method in the clause 4.1.4
Parameter Initializing Restoring Factory Default Settings .