Chziri ZVF200-M User Manual page 51

Vector inverter
Table of Contents

Advertisement

Present Fault Record
P 73
P 74
Second Most Recent Fault Record
P 75
Third Most Recent Fault Record
no fault occurred
00
Over-current (oc)
01
Over-voltage (ov)
02
Overheat (oH)
03
04
Overload (oL)
Overload 1 (oL1)
05
External Fault (EF)
06
CPU failure 1 (CF1)
07
CPU failure 3 (CF3)
08
Hardware Protection Failure (HPF)
09
Settings
Over-current during acceleration (OCA)
10
Over-current during deceleration (OCd)
11
Over-current during steady state operation (OCn)
12
Ground fault or fuse failure (GFF)
13
Low voltage (not record)
14
3 Phase Input Power Loss
15
CPU Failure (CF2)
16
External Base-Block (bb)
17
Overload 2 (oL2)
18
Auto Adjustable accel/decel failure (cFA)
19
Software protection code (codE)
20
P 76
Parameter Lock and Configuration
00
All parameters can be set/read
01
All parameters are read-only
Settings
02-08
Reserved
09
Resets all parameters to 50Hz factory defaults
10
Resets all parameters to 60Hz factory defaults
-96-
Chapter 6 Parameters
Factory Setting
00
Factory Setting
00
Factory Setting
00
Factory Setting
00
This parameter allows the user to reset the drive to factory settings.
Can set parameter to 01 or 08 to avoid person change the parameter
setting by disoperation, when action abnormal by parameter fault or
change. Can set the parameter to 09(factory setting) then adjust again.
When P76 set to 08.key board locked. All parameter
can't amend.
Need unlock the keyboard if want amend parameter.
Ways below;
1. Outage of inverter till no display.
TIP
2. Hold "ENTER" key then supply power. After 30
seconds and see P00 then let go.
3. Set P76 parameter to 00.
P 77
Time for Auto Reset the Restart Times after Fault
Settings
0.1 to 6000.0 sec
If there is no fault in the period of this setting, it will reset the rest restart
times that used after fault to the setting of restart times.
PLC Operation Mode
P 78
00
Disable PLC operation
01
Execute one program cycle
02
Continuously execute program cycles
Settings
03
Execute one program cycle step by step (separated by "STOP")
Continuously execute program cycles step by step (separated
04
by "STOP")
The parameter application can used to control the running process of
small machine. Food Processing Machine, washing equipment. And
can replace the control line of traditional relay .switch and timer
There are lots of setting while use this function. And can't make any
mistake. Please see below sample carefully:
-97-
Chapter 6 Parameters
Factory Setting
60.0
Factory Setting
00