Appendix - Chziri ZVF200-M User Manual

Vector inverter
Table of Contents

Advertisement

Appendix 1 Optional Parts
All the following optional parts can be ordered with us if needed.
1. Brake Assembly
The brake assembly consists of two parts: braking unit and braking resistor.
It is necessary to install a brake assembly on the occasion that quick stop
is required though there is a heavy potential load (e.g., elevator) or inertia
load.
Appendix 1-1 Recommended Brake Assembly Matching Specifications
Braking unit
Inverter
voltage Motor(kw)
Model quantity
0.4
Built-in
0.75
Built-in
1.5
Built-in
220V
2.2
Built-in
3.7
Built-in
5.5
Built-in
0.75
Built-in
1.5
Built-in
2.2
Built-in
380V
3.7
Built-in
5.5
Built-in
7.5
Built-in
-136-

Appendix

Braking resistor
Resistor
Recommended
Quantity
specification
Resistance value
80W200
80W200
1
80W200
80W200
1
160W100
160W100
1
300W70
300W70
1
400W40
400W40
1
500W30
500W30
1
80W750
80W750
1
160W400
160W400
1
300W250
300W250
1
400W150
400W150
1
600W150
600W150
1
800W75
800W75
1
This series product have built-in braking. Can connect
external braking resistor.
When install braking resistor. please consider the safety
TIP
of ambient environment.
2.Remote-operated adapter and extended cable
There are two selections available for remote operation on the inverter
ZVF200 series. If it is operated at short range ( 15m), just extend the shielding
cable directly and connect it to the operator panel. Our company can provide
a range of extended shielding cables with different specifications such as
1m, 1.5m, 2m, 3m, 5m and 10m. If there is any special requirement on cable
length, just place an order with the company.
When proceeding remote controlled wiring, DO disconnect
power supply. Installation Procedure Proceed in accordance
WARNING
with the methods described in Clause 3.2.2 in this manual.
3. Serial Communication (COM)
The standard machin e type of the inverter ZVF200-M series does have RS232
and RS485 communication function. The control terminals of standard
RS232 and RS485 communication interface may connect to RS232 or RS485
communication cable to realize network control or ratio interlocking control.
RS232 and RS485 serial communication protocol for the inverter ZVF200-M
series can be operated under Windows98/2000. And the monitoring software
for this series, featured by friendly man-machine operation interface, can
easily realize networking operation and perform monitoring and other
functions of the inverter. Please contact the service centre of this company
or its agents if it is needed.
-137-
Appendix

Advertisement

Table of Contents
loading

Table of Contents