Chapter 3 Installation And Wiring; Installation - Chziri ZVF200-M User Manual

Vector inverter
Table of Contents

Advertisement

Chapter 2 Introduction to the Product
Item
Over Current .Over current .Under voltage .external
Protection Function
fault .Overload. Ground fault. Overheating .
Altitude 1000m or less .Keep from corrosive gas .
Installation location
liquid and dust
Ambient Temperature -10
to 40
( -10
Ambient Humidity
Below 90% RH (no-condensing ).
<0.5G
Vibration
Storage temperature -20
to 60
Protection Level
IP20
Forced air cooling
Cooling mode
Wall mounted

Installation

-14-
Item Description
to 50
without blind plate )

Chapter 3 Installation and Wiring

Chapter 3 Installation and Wiring
3.1 Installation
3.1.1 Use the inverter in the following environmental conditions:
Altitude: Maximum 1000m above sea level
Ambient Temperature: -10~+45
Humidity: 20~90% RH (Non-condensing)
Ambient: Indoor places free from direct exposure to sunlight, dust,
corrosive gas, flammable gas, oil mist, steam, drip and salt
Vibration: < 0.5G
3.1.2 Installation Space and Direction
To get better cooling effect and convenience of maintenance, the
inverter shall be installed vertically with enough space left (refer to the
figure 3-1). When two and two more inverters are fixed in the same cabinet,
it is recommended to fix them in parallel and horizontally to reduce heat
produced by them (refer to the figure 3-2).When there is a must to fix them
vertically, please fix an insulating board between them so that the heat
produced by the lower one could not have direct influence on the upper
one (refer to the figure 3-3)
Figure 3-1 Installation
Figure 3-2 Multi-piece
Space
Parallel Installation
-15-
[Bare Machine: -10~+50 ]
Figure 3-3 Multi-piece
Vertical Installation