INSTRUCTIONS
CAUTION
Replacement lamps must comply with CFR 21 1040.20 When ordering lamps, include
model number and serial number.
5400
Replace only with Rave 160 APR 1841, Rave 12071 R 1989 & Hereaus E-400 HPT lamps for
facial.
6400
Replace only with Rave PREFFERED 1885, System Varius 80010522 & Hereaus OHC 560
500W lamps for facial.
REPLACING LOW-PRESSURE TANNING LAMPS
5400 and 6400
BENCH
1. Disconnect power from unit.
2. Unlock the front bench acrylic locks (use 5/32 allen wrench)
3. Hinge the acrylic open by lifting up on the front edge.
Note: The acrylic should stay in the open position.
4. Remove the inner acrylic and set aside. (6400 only)
5. Turn the bi-pin lamp 90 degrees and remove from lamp holder.
6. Align the bi-pin lamp, slide the top and bottom into the lamp holder turn 90
degrees.
7. Reinstall inner acrylic (6400 only)
8. Clean and close the acrylic.
9. Use 5/32 allen wrench to lock bench acrylic.
10. Reconnect power to unit.
CANOPY
1. Disconnect power from unit.
2. Remove the screws from the canopy handle/acrylic retainer.
3. Holding the acrylic, hinge the handle/acrylic retainer open and remove
acrylic.
4. Turn the bi-pin lamp 90 degrees and remove from lamp holder.
5. Align the bi-pin lamp, slide the top and bottom into the lamp holder turn 90
degrees.
6. Clean acrylic and reinstall.
7. Hinge the handle/acrylic retainer closed and reinstall the screws.
8. Reconnect power to unit.
IMPORTANT NOTE – 2 people are required when removing and installing
canopy acrylics on these units, 1 person at each end of bed.
www.heartlandtan.com
RELAMPING
15
12/06