Advertisement

2800
3400
www.heartlandtan.com
10/27
Part # 54057

Advertisement

Table of Contents
loading

Summary of Contents for Heartland Ovation 2800

  • Page 1 2800 3400 www.heartlandtan.com 10/27 Part # 54057...
  • Page 2: Table Of Contents

    Table of Contents WARNINGS AND CAUTIONS MANDATORY READING SKIN GUIDE 2800 SPECIFICATIONS AND REQUIREMENTS 2800 EXPOSURE SCHEDULE 3400-3400/3 SPECIFICATIONS AND REQUIREMENTS 3400-3400/3 EXPOSURE SCHEDULE 10-11 3400R-3400/3 R SPECIFICATIONS AND REQUIREMENTS 3400R-3400/3 R EXPOSURE SCHEDULE 13-14 3400S-3400/3 S SPECIFICATIONS AND REQUIREMENTS 3400S-3400/3 S EXPOSURE SCHEDULE 16-17 REPAIRS,SERVICE,REPLACEMENT PARTS, LAMPS, AND EYE PROTECTION...
  • Page 3: Warnings And Cautions

    WARNINGS AND CAUTIONS Certain drugs - particularly those designed to produce photosensitivity may cause individuals under the influence of this type drug to experience adverse effects and those people should avoid exposure to UV sources of all type. Doctors will advise persons taking these drugs of possible adverse effects.
  • Page 4: Mandatory Reading

    See Lamp Guide for the appropriate lamp replacements for your Tanning Bed. Should you have any questions regarding the proper use of your tanning system, contact: Heartland Tanning, Inc. 1-800-554-8268 8:00AM to 5:00PM (CST) www.heartlandtan.com 10/27...
  • Page 5: Skin Guide

    Use only creams, oils or lotions (particularly suntan lotions) that are recommended by Heartland Tanning, Inc. Equally important - many facial makeups have oil bases and sun block which should be removed prior to a session.
  • Page 6 SPECIFICATIONS EXPOSURE SCHEDULE www.heartlandtan.com 10/27...
  • Page 7 2800 SPECIFICATIONS 28 Lamp Heartland Rave system - 20 minute session (8) Heartland Rave 5071 100 watt lamps in canopy • (6) Heartland Rave 5059 80 watt lamps in canopy • (14) Rave 5071 100 watt lamps in bench •...
  • Page 8 This system is intended to be used only with Rave 5071 1825, Rave 5059 1824 & Heraeus E-400 HPT for facials. Sales or Service Questions Heartland Tanning, Inc. • Lee’s Summit, MO • 1-800-554-8268 Follow recommended exposure schedule for skin type. NOTE: See Skin Guide (pg. 3) for help choosing the proper skin type.
  • Page 9 Questions au sujet des ventes ou de service : Heartland Tanning, Inc. • Lee’s Summit, MO – 1-800-554-8268 Suivez le programme recommandé d’exposition pour le type de peau. Cette appareil utilise des lampes de l’ultraviolet A. Remplacez seulement avec les lampes de marque Rave 5071 100W Rave 5059 80W et Hereaus 400W (ampoule faciale de bronzage, là...
  • Page 10 SPECIFICATIONS EXPOSURE SCHEDULE www.heartlandtan.com 10/27...
  • Page 11 3400 & 3400/3 SPECIFICATIONS 34 Lamp Heartland Rave system - 20 minute session • (18) Heartland Rave 5071 100 watt lamps in canopy • (16) Heartland Rave 5071 100 watt lamps in bench • (3) 400 watt facial lamps(3400/3) • T-Max timer on board (T-Max wireless compatible) •...
  • Page 12 HPA 400/30 S & Heraeus E-400 HPT lamps (facial unit, where applicable). Sales or Service Questions Heartland Tanning, Inc. • Lee’s Summit, MO • 1-800-554-8268 Follow recommended exposure schedule for skin type. NOTE: See Skin Guide (pg. 3) for help choosing the proper skin type.
  • Page 13 Questions au sujet des ventes ou de service : 1-800-554-8268 Heartland Tanning, Inc. • Lee’s Summit, MO – Suivez le programme recommandé d’exposition pour le type de peau. Cette appareil utilise des lampes de l’ultraviolet A. Remplacez seulement avec les lampes de marque Rave 5071 100W et Hereaus 400W (ampoule faciale de bronzage, là...
  • Page 14 3400R & 3400R/3 SPECIFICATIONS 34 Lamp Heartland Rave system - 15 minute session • (18) Heartland Rave 10071 R 100 watt lamps in canopy • (16) Heartland Rave 10071 R 100 watt lamps in bench • (3) 400 watt facial lamps(3400R/3) •...
  • Page 15 Heraeus E-400 HPT lamps (facial unit, where applicable). Sales or Service Questions Heartland Tanning, Inc. • Lee’s Summit, MO • 1-800-554-8268 Follow recommended exposure schedule for skin type. NOTE: See Skin Guide (pg. 3) for help choosing the proper skin type.
  • Page 16 Questions au sujet des ventes ou de service : 1-800-554-8268 Heartland Tanning, Inc. • Lee’s Summit, MO – Suivez le programme recommandé d’exposition pour le type de peau. Cette appareil utilise des lampes de l’ultraviolet A. Remplacez seulement avec les lampes de marque Rave 10071 R 100W lamps et Hereaus 400W (ampoule faciale de bronzage, là...
  • Page 17 3400S & 3400S/3 SPECIFICATIONS 34 Lamp Heartland Rave system - 10 minute session • (18) Heartland Rave SELECT 100 watt lamps in canopy • (16) Heartland Rave SELECT 100 watt lamps in bench • (3) 400 watt facial lamps(3400S/3) • T-Max timer on board (T-Max wireless compatible) •...
  • Page 18 400/30 S and Heraeus E-400 HPT (for facials, where applicable). Sales or Service Questions Heartland Tanning, Inc. • Lee’s Summit, MO • 1-800-554-8268 Follow recommended exposure schedule for skin type. NOTE: See Skin Guide (pg. 3) for help choosing the proper skin type.
  • Page 19 Questions au sujet des ventes ou de service : 1-800-554-8268 Heartland Tanning, Inc. • Lee’s Summit, MO – Suivez le programme recommandé d’exposition pour le type de peau. Cette appareil utilise des lampes de l’ultraviolet A. Remplacez seulement avec les lampes de marque Rave Select 100W et Hereaus 400W (ampoule faciale de bronzage, là...
  • Page 20: Repairs,Service,Replacement Parts, Lamps, And Eye Protection

    REPAIRS - SERVICE REPLACEMENT PARTS LAMPS EYE PROTECTION If you are in need of any of the above mentioned products or services, you should contact the dealer/distributor through whom you purchased your unit. In the event that you are unable to do so, please call our Service Department for assistance: 1-800-554-8268 NOTE: All repairs and replacement components including, but not limited...
  • Page 21: Care And Cleaning

    CARE AND CLEANING After each session is completed, spray acrylic with a specially formulated UVT (ultra-violet transmitting) acrylic cleaner. Wipe the acrylic with a clean cloth. The acrylic should never be wiped with a dry cloth because this will generate a slight static charge which will attract dust. A mild liquid detergent and water solution can be used temporarily in place of acrylic cleaner.
  • Page 22: Lamp Guide

    LAMP GUIDE www.heartlandtan.com 10/27...
  • Page 23: Relamping Instructions

    RELAMPING INSTRUCTIONS 2800 Replace only with Rave 5071 100W lamps, Rave 5059 80W lamps and Hereaus 400W lamps (Facial unit, where applicable) 3400, 3400/3 Replace only with Rave 5071 100W lamps and Hereaus 400W lamps (Facial unit, where applicable) 3400R, 3400R/3 Replace only with Rave 10071 R 100W lamps and Hereaus 400W lamps (Facial unit, where applicable) 3400S, 3400S/3...
  • Page 24 CAUTION: Replacement lamps must comply with CFR 21 1040.20 When ordering lamps, include model number and serial number. REPLACING HIGH-PRESSURE FACIAL LAMPS 2800 1. Disconnect power from unit. 2. Remove three (3) quarter-turn fasteners on the rear of the canopy and remove the acrylic retainer.
  • Page 25 REPLACING HIGH-PRESSURE FACIAL LAMPS 3400 1. Disconnect power from unit. 2. Remove two (2) quarter-turn fasteners at the front edge of the acrylic using a #2 Phillips screwdriver. 3. Pull the front edge of the acrylic rail down from the canopy allowing the acrylic to hinge down from the back of the canopy.
  • Page 26 INSTALLATION www.heartlandtan.com 10/27...
  • Page 27 Congratulations on your purchase of Applied Digital, Inc.’s T-Max Series of tanning bed timers. The T-Max Series is designed for complete automation and control of your tanning equipment. A Heartland Timer is an OEM board that can be installed in a tanning bed or tanning booth. Each Heartland Timer can...
  • Page 28 0 with no periods displayed. Setting the address NOTE: If you are using the Heartland Timer as an independent timer, you don’t need to set the address on the Heartland Timer. Press and hold the Start/Stop and Up buttons simultaneously on the Heartland Timer until a .1 appears on the display.
  • Page 29 Redisplay 0 = After a session ends and the clean room is cleared, the Heartland Timer will show a 0. 1 = After session ends and the clean room is cleared, the Heartland Timer will show the last session time entered. 2 = After the session ends and the clean room is cleared, the max time will show on the Heartland Timer.
  • Page 30 4. Press the Up or Down button until the desired delay time is displayed. The highest delay time that can be set on the Heartland Timer is 10 minutes. If you want no delay time, set the display to 0. If you set the delay time to 0, the session time will start immediately after the Start/Stop button is pressed.
  • Page 31 T-Max 3A (see RJ-22 ports for T-Max Series timers on page 29, figure B). Configuration Set the address on the Heartland Timer in the tanning room to 1. Set the address on the T-Max 3A to 0.0. For setting the delay, refer to the T-Max 3A User’s Guide.
  • Page 32 Note: Delay is controlled by the T-Max Manager, the T-Max Manager/Plus/Pro or the software you are using if you are using a computer. It is not necessary to set the delay on the Heartland Timer. Refer to the T-Max Manager or T-Max Manager/Plus/Pro User’s Guide for operation.
  • Page 33 2. Connect the two actuator wires from the FST or Database timer to the TPI input in the back of the Heartland timer. When a session is started, the FST timer will place 5v on these two wires. If you are using a database Series timer, 24 volts will be applied.
  • Page 34 NOTE: The Heartland timer can not be used as a stand alone timer in the TPI mode. If the FST or Database Series timers are in delay the Heartland Timer will show a 0. However, pressing the Start/Stop button on the Heartland Timer will eclipse the delay time and start the session.
  • Page 35 Figure A - Front View Of The Heartland Timer Figure B - Power Board Location RJ-22 CONNECTOR TO DISPLAY PORT 110V SWITCH OUTPUT FOR TPI NOT USED SWITCH INPUT FOR TPI 110V 5V or 24V INPUT or NOT USED CONTACT CLOSURE...
  • Page 36 Figure C - Connecting The Heartland Timer to a T-Max Series Front Desk Location T-Max Manager/Plus (or T-Max Manager) OPTIONAL COMPUTER 50' MODULAR CABLE w/RJ-22 CONNECTORS ARE USED TO CONNECT THE SERIES AS SHOWN. It does not matter in which order the rooms are connected. The only requirement is that there is a continuous connection from the T-Max Manager through each room in the T-Max Series daisy-chain.
  • Page 37 ASSEMBLY INSTRUCTIONS www.heartlandtan.com 10/27...
  • Page 38 2800 ASSEMBLY INSTRUCTIONS TOOLS NEEDED: • 7/16" Socket, 9/16" Socket, 13mm Socket • 5/32" Allen Wrench and 1/4" Allen Wrench (Both Provided) • #2 Phillips Screwdriver or screw gun • Two (2) or more people STEP 1. Position the bench upside down. Using the 3/8"-16x1" bolts and the 3/8"...
  • Page 39 STEP 3. Turn the unit right side up and install the hinge plate.(Fig. B) Fig. B STEP 4. Place the bench in its final location inside of the salon. STEP 5. Place the canopy on top of the bench aligning the bench and canopy hinge plates.
  • Page 40 STEP 6. Mount the shocks to the unit. The shock mounting holes are located towards the rear of the unit on both sides of the bench and canopy. (Fig. D) NOTE: ATTACH CYLINDER OF THE SHOCK TO THE CENTER MOUNTING HOLES IN CANOPY AND THE SHAFT TO THE CENTER MOUNTING HOLES IN THE BENCH.
  • Page 41 STEP 8. Install RJ-22 cable from your communication network (see timer section for details). STEP 9. Connect the jumper cord located on the back of the canopy, to the terminal on the back of the bench. (Fig. F) Fig. F STEP 8.
  • Page 42 ASSEMBLY INSTRUCTIONS www.heartlandtan.com 10/27...
  • Page 43 3400 ASSEMBLY INSTRUCTIONS TOOLS NEEDED: • 7/16" Socket, 9/16" Socket, 13mm Socket • 5/32" Allen Wrench and 1/4" Allen Wrench (both provided) • Two (2) or more people STEP 1. Position the bench upside down and determine left and right legs.
  • Page 44 STEP 2. Turn the unit right side up and place the canopy on top of the bench, aligning the bench and the canopy hinge plates. Bolt the hinge plates together using the 1/2"x1/4" shoulder bolts, 3/8" nuts, 9/16" socket, and 1/4" Allen wrench (both provided) (Fig.
  • Page 45 STEP 6. Locate black timer wire coming from bottom of the bench. Plug the black timer wire into the display port on front of the ballast tray. (Fig.4) See timer section for details. Fig. 4 STEP 7. Place the ballast tray between the legs of the unit with the Display Port facing the front of the unit.
  • Page 46 STEP 8. Attach the two (2) leg end cap mounting brackets to the bottom outside section of each leg using the 1/4"-20x7/8" bolts provided. (Fig 6) STEP 9. Position the end caps on either side of the bench. Attach using the small 1/4 turn fasteners provided.
  • Page 47 WIRING www.heartlandtan.com 10/27...
  • Page 48 PINK GREY PURPLE ORANGE YELLOW BLUE TIMER TIMER PINK GREY PURPLE ORANGE YELLOW BLUE www.heartlandtan.com 10/27...
  • Page 49 PINK GREY PURPLE ORANGE YELLOW BLUE PINK GREY PURPLE ORANGE YELLOW BLUE www.heartlandtan.com 10/27...
  • Page 50 2800 BALLAST TRAY COMPONENTS AND LAYOUT TERM. STRIP 400 WATT BALLAST 40 AMP CONTACTOR FUSE BLOCK 100 WATT BALLAST RELAY 30 uf CAPACITOR 13.5 uf CAPACITOR www.heartlandtan.com 10/27...
  • Page 51 WIRING www.heartlandtan.com 10/27...
  • Page 52: 3400 Wiring

    3400 WIRING HARNESS CORD #1 / RECEPTACLE #1 HARNESS CORD #2 / RECEPTACLE #2 RECEPTACLE PLUG RECEPTACLE PLUG PIN# PIN# COLOR LOCATION LOCATION COLOR LOCATION LOCATION Blue Lamp 1 Head End Ballast 1-1 Blue Lamp 9 Head End Ballast 2-1 Yellow Lamp 2 Head End Ballast 1-2...
  • Page 53 3400 WIRING HARNESS CORD #4 / RECEPTACLE #4 HARNESS CORD #3 / RECEPTACLE #3 RECEPTACLE RECEPTACLE PLUG PLUG LOCATION LOCATION LOCATION PIN# COLOR LOCATION PIN# COLOR Blue Lamp 10 Head End Blue Lamp 1 Head End Ballast 3-1 Ballast 4-1 Lamp 11 Head End Lamp 2 Head End Ballast 3-2...
  • Page 54 3400 100 WATT BALLAST 13.5 uf CAPACITOR BALLAST TRAY COMPONENTS 400 WATT BALLAST AND LAYOUT: 40 AMP CONTACTOR CPC RECEPTACLE #3 CPC RECEPTACLE #1 CPC RECEPTACLE #4 CPC RECEPTACLE #2 TIMER BOARD FAN CONTROL BOARD 3-6 3-7 3-8 3-9 4-9 4-8 4-7 TERM.
  • Page 55 3400 WIRING DIAGRAM www.heartlandtan.com 10/27...
  • Page 56: Limited Warranty

    If the warranty card is not registered, proof of purchase from Heartland Tanning, Inc. or its authorized dealer or distributor will be required prior to any consideration on warranty claims. This could result in service delays.

Table of Contents