Heartland Ovation 5400 Owner's Manual page 24

Table of Contents

Advertisement

To insure safety for the user and to protect the salon owner's investment the 5400/6400 Timer
has multiple levels of protection. If a fault occurs the 5400/6400 Timer will shut down and
display the fault. If the salon is running on a T-Max™ system the front controlling timer will sound
an alarm and display a fault. The display on the 5400/6400 Timer will prompt you to reset if
possible. If you have a fault that will not allow you to reset, cycle the power to the unit OFF
and then back ON. If this still does not allow you to resume use refer to the owner's manual
and any stored faults can be accessed from a T-Max™ controlling timer. The possible stored
faults will be found in parameter 35 and 36. These faults are listed below.
Parameter 35 Last Error
92 = Current On Error
93 = Current Off Error
70 = Special Error (check parameter 36 for details)
98 = Temperature Error
Parameter 36 Last Special Error Stored
3 = Voltage Error
Trouble Shooting Procedure
3 = Voltage Error-Turn Power OFF before any type of maintenance is started.
1. Cycle power OFF and then back ON. Check display to see if fault resets. IF the fault
does not reset a voltage measurement will need to be taken at the control box. If
voltage is above or below the preset value, a Buck/Boost transformer may be
needed.
2. If no problem is found, contact the manufacture for assistance.
REMOTE SINGLE BED CONTROL
Remote Single Bed Control is the ability to control a single tanning bed from a remote
location. T-Max™ 3A at the remote location is required for this configuration.
Wiring
Wire the Heartland Timer to the tanning bed. Apply power to the T-Max™ 3A as described in
their respective User's Guides. Run the provided modular cable from the tanning room to the
remote T-Max™ 3A. Connect the modular cable to one of the RJ-22 ports on the Heartland
Timer and T-Max™ 3A (see RJ-22 ports for T-Max™ Series timers on page 16, figure B).
Configuration
Set the address on the Heartland Timer in the tanning room to 1. Set the address on the
T-Max™ 3A to 0. For setting the delay, refer to the T-Max™ 3A user's guide.
Note: When setting the address on the Heartland Timer in the tanning room, the power to the
front desk T-Max™ 3A must be off.