Replacing High-Pressure Facial Lamps - Heartland Ovation 5400 Owner's Manual

Table of Contents

Advertisement

REPLACING HIGH-PRESSURE FACIAL LAMPS

5400 and 6400
1. Disconnect power from unit.
2. Remove two (2) quarter-turn fasteners at the front edge of the acrylic using a
#2 Phillips screwdriver.
3. Hinge the front handle/acrylic retainer down from the canopy allowing the
acrylic to hinge down from the back of the canopy.
4. Remove acrylic from the hinge rail exposing the facial assembly.
5. While holding the facial glass, press the two (2) retaining tabs back using your
thumb and set the facial glass aside.
6. Grasp the facial lamp from one end pressing towards the opposite end to
release the facial lamp from the lamp holder.
7. Replace the facial lamp.
NOTE
ONLY GRASP FACIAL LAMP FROM EITHER END; ALWAYS USE ALCOHOL TOWEL
PROVIDED WITH LAMP TO WIPE OFF LAMP AFTER INSTALLATION.
8. Reverse the procedures above to reassemble.
CAUTION
DO NOT CHECK FACIAL LAMP OPERATION WITH FACIAL GLASS CASSETTE
REMOVED. ALWAYS WEAR UV PROTECTIVE EYEWEAR WHEN REPLACING LAMPS AND
CHECKING OPERATION.
www.heartlandtan.com
16
12/06