Heartland Ovation 5400 Owner's Manual page 26

Table of Contents

Advertisement

OTHER FEATURES
Clean Room
Once a session time has elapsed, the display will show the session as over and that the bed
needs cleaning. To clear the clean room indication, press and hold the Up button on the
5400/6400 Timer in the tanning room until the Ovation screen appears. To disable the clean
room feature, set parameter 9 to a 0.
Cool Down Mode
The cool down mode is when the bed cools down after a session has ended. The factory
default setting is 10 minutes. Once the bed has been cleaned a new session can be sent to
the 5400/6400 timer while in cool down mode.
Lamp Hours
Used to check and change Lamp Hours (or any other parameter).
TPI (Third Party Input) Mode
If you are using a FST or Database Series timers, you will need to place the 5400/6400 Timer in
the TPI mode.
Connecting the TPI Input:
1. Set Parameter 19 to a 1.
2. Connect the two contact wires from the in room start button from the FST or database
timer system to the J4 connection.
Operating in TPI Mode:
When a session is started, the closed contact will be applied to the TPI input. The display on the
5400/6400 Timer will show the maximum time and count down. When the session ends, the
closed contact will be removed from the TPI input and the bed will turn off. Any remaining
session time showing on the 5400/6400 Timer will be eclipsed.
NOTE: The 5400/6400 timer cannot be used as a stand alone timer in the TPI Mode.
www.heartlandtan.com
23
12/06

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ovation 6400