Troubleshooting; List Of Warning And Error States - Datalogic UniQ 1150-1X41 Product Reference Manual

Infrared fiber laser marker
Table of Contents

Advertisement

TROUBLESHOOTING

If a problem occurs during operation, first check the following troubleshooting. If you
cannot fix the problem, contact Datalogic customer service (see "Technical Support" on
page vi).

List of warning and error states

STATUS LED
DESCRIPTION
Blinking ORANGE
Warning invalid start
(1 Hz)
sequence
Blinking ORANGE
Warning laser warm
(0.5 Hz)
up
Blinking RED at
System Error
Power ON
Blinking RED after
System Error
KEY activation
POSSIBLE
ACTION
CAUSE
Incorrect turning-on
Repeat the "Turning On
sequence
sequence" on page 44
Laser marker leaves
No action. The duration of the
the interlock error
laser warm up state is approxi-
state
mately 15 seconds
- Check Interlock connector sig-
nals (see "Interlock" on page 21)
Interlock error
- Check Interlock connector
presence
- Check X1.10 - CONNEC-
TOR_PRESENCE input signal of
the X1 - Command Box connec-
tor (see "X1 - Command Box
(Laser Control)" on page 25):
Connector Presence
HIGH level: normal operation;
error
LOW level or disconnected: sys-
tem error
- Check if X1 - Command Box
connector is present
Laser Source Error:
Use Profilab application to con-
- Temperature error
nect to the laser source and
- Master Oscillator
report the error status code to
Error
Datalogic Technical Support
- Back reflection error
TROUBLESHOOTING
X1 - COMMAND
BOX CONNECTOR
OUTPUT STATE
SYSTEM_ALARM
OFF
POWER_ON
OFF
ENABLE_OUT
OFF
SYSTEM_ALARM
OFF
POWER_ON
OFF
ENABLE_OUT
OFF
SYSTEM_ALARM
ON
POWER_ON
OFF
ENABLE_OUT
OFF
SYSTEM_ALARM
ON
POWER_ON
OFF
OFF
ENABLE_OUT
PRODUCT REFERENCE GUIDE
69

Advertisement

Table of Contents
loading

Table of Contents