TECHNICAL SPECIFICATIONS
LASER MARKER STATES
Normal Operation States
STATE
SYSTEM BOOTING UP
WAIT FOR START
STANDBY SHUTTER
CLOSED
READY
Error States
STATE
ERROR
SYSTEM ERROR
INTERLOCK ERROR
CBOX ERROR
TEMPERATURE ERROR
BACK REFLECTION
ERROR
MASTER OSCILLATOR
ERROR
Warning State
STATE
WARNING INVALID
START SEQUENCE
WARNING LASER
WARMUP
32
UNIQ™
DESCRIPTION
This state occurs since the laser marker is
switched on until Laser Engine has been loaded
and no errors occurred
In this state the laser marker cannot emit IR lasers
radiation and Aiming and Focus beam cannot be
activated
In this state Aiming and Focus beam can be acti-
vated while the laser marker cannot emit IR laser
radiation
In this state the laser marker is able to emit IR
laser radiation
DESCRIPTION
This state occurs if the laser marker detects an
error that prevents normal operation
DESCRIPTION
This error occurs if the INTERLOCK safety function is ON. To reset the
error, set INTERLOCK safety function to OFF and repeat the turning on
sequence
This error occurs if the CONNECTOR_PRESENCE signal (pin 10 Com-
mand Box connector) is LOW or not connected. To reset the error, set
CONNECTOR_PRESENCE signal to HIGH value and repeat the turning
on sequence
This error occurs if the temperature inside the laser marker is out of
the operative range. To reset the error, a Laser marker restart is
required
This error occurs if high optical power is reflected back to the laser
source. To reset the error, a Laser marker restart is required
This error occurs if the laser source detects an internal failure. To
reset the error, a Laser marker restart is required
DESCRIPTION
This state occurs if the turning on sequence has
not been followed. To restore normal laser marker
operation, repeat the turning on sequence
This state occurs when the laser marker leaves the
interlock error state. The duration of the laser
warm-up state is approximately 15 seconds
STATUS LED
Blinking
Steady
Steady
Steady
STATUS LED
Blinking
STATUS LED
Blinking
Blinking