X1 - Command Box (Laser Control); Panel Connector - Datalogic UniQ 1150-1X41 Product Reference Manual

Infrared fiber laser marker
Table of Contents

Advertisement

X1 - Command Box (Laser Control)

Panel connector

Socket Sub-D, 25 pins, female.
PIN
SIGNAL
X1.1
24V_ENABLE_B
X1.2
EXT_ENABLE_B
X1.3
RESERVED
X1.4
EXT_24V
X1.5
EXT_24V
X1.6
EXT_24V
X1.7
24V_ENABLE_A
X1.8
EXT_ENABLE_A
X1.9
BUSY
CONNECTOR_PRES-
X1.10
ENCE
X1.11
START_MARKING*
X1.12
EXT_KEY
X1.13
STOP_MARKING*
X1.14
RESERVED
X1.15
RESERVED
X1.16
RESERVED
X1.17
END
X1.18
POWER_ON
X1.19
GND
X1.20
SYSTEM_ALARM
Figure 17: Female panel socket Sub-D 25 (front view)
TYPE***
Output power
Auxiliary 24V DC power supply available for EXT_ENABLE_B (max 125mA)
supply
Secondary external ENABLE signal:
Digital Input
- HIGH level: contact closed
- LOW level or disconnected: contact opened
-
DO NOT CONNECT
Output power
Auxiliary 24V DC power supply available for drive input logical HIGH (max
supply
125mA)
Output power
Auxiliary 24V DC power supply available for drive input logical HIGH (max
supply
125mA)
Output power
Auxiliary 24V DC power supply available for drive input logical HIGH (max
supply
125mA)
Output power
Auxiliary 24V DC power supply available for EXT_ENABLE_A (max 125mA)
supply
Primary external ENABLE signal:
Digital Input
- HIGH level: contact closed
- LOW level or disconnected: contact opened
This signal is used to know if the current spooler is executing (marking in
progress):
Digital Output
- ON during marking process
This signal is used to check the presence of the Command Box connector:
Digital Input
- HIGH level: normal operation
- LOW level or disconnected: laser marker faulty
This signal is used to start to the marking process when a document or a
sequence is running in AUTO MODE** or WORK MODE**:
Digital Input
- HIGH level pulsed signal start the marking process
External KEY signal:
Digital Input
- HIGH level: contact closed
- LOW level or disconnected: contact opened
This signal is used to stop the marking process:
Digital Input
- HIGH level pulsed signal stop the marking process
-
DO NOT CONNECT
-
DO NOT CONNECT
-
DO NOT CONNECT
This signal is used to know if the marking process is finished:
Digital Output
- ON at the end of marking process
This signal is used to know if the laser marker is already warmed up:
Digital Output
- ON when the laser is in STAND_BY or READY state
Ground
Ground reference
This signal is used to know if the laser marker is in booting up state or in
error state:
Digital Output
- ON during BOOTING UP
- ON in case of system error
CONNECTORS SPECIFICATIONS
DESCRIPTION
PRODUCT REFERENCE GUIDE
25

Advertisement

Table of Contents
loading

Table of Contents