Product overview
Technical data
Technical data
Technology
Nominal voltage
Capacity
Ripple current
Internal resistance
Surge voltage protection
Recommended ballast resistor
Overvoltage control range
Ballast resistor clock rate
Electrical isolation
Diagnostics
Message to E-Bus
PE contact
Shield connection
Current consumption from E-Bus
Bit width in the process image
Electrical connection to mounting rail
Electrical isolation
Renewed infeed
Connection facility to additional power con-
tact
Side by side mounting on EtherCAT Termi-
nals with power contact
Side by side mounting on EtherCAT Termi-
nals without power contact
Configuration
Weight
Permissible ambient temperature range (dur-
ing operation)
Permissible ambient temperature range (dur-
ing storage)
Permissible relative humidity
Dimensions (W x H x D)
Mounting [} 73]
Vibration/shock resistance
EMC resistance burst/ESD
Protect. class
Installation pos.
Approval
LEDs und Anschlussbelegung EL9570
LED
Overload
62
EL9570
buffer capacitor
50 V
500 µF
10 A in continuous operation
< 10 mΩ
> 56 V
10 Ω, 10 W typ.
±2 V
load-dependent, 2-point control
1500 V
-
-
no
-
-
0
-
-
-
-
yes, left side without PE
yes
no address or configuration settings
approx.. 90 g
0°C ... +55°C
-25°C ... +85°C
95%, no condensation
approx. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)
on 35 mm mounting rail conforms to EN 60715
conforms to EN 60068-2-6/EN 60068-2-27
conforms to EN 61000-6-2/EN 61000-6-4
IP 20
variable, see chapter "Mounting of Passive Terminals [} 83]"
CE
ATEX [} 84]
Color
Meaning
green
off
No error
on
Overload, energy will be absorbed in the connected
ballast resistor
Version: 3.9
EL9xxx