Technical Data
Technical Data
Input voltage
Output current for E-bus supply
Power contact voltage
Power contact current load
Current consumption from E-Bus
Electrical isolation
Diagnosis
Electrical connection to mounting rail
PE contact
Renewed infeed
Connection facility to additional power con-
tact
Side by side mounting on Bus Terminals
with power contact
Side by side mounting on Bus Terminals
without power contact
Bit width in the process image
Configuration
Weight
Permissible ambient temperature range
(during operation)
Permissible ambient temperature range
(during storage)
Permissible relative humidity
Dimensions (W x H x D)
Mounting [} 73]
Vibration/shock resistance
EMC resistance burst/ESD
Protect. class
Installation pos.
Approval
Connection EL9400, EL9410
Terminal point
Indication
No.
+24 V for E-Bus
1
+24 V
2
0 V
3
PE
4
0 V for E-Bus
5
+24 V
6
0 V
7
PE
8
56
EL9400
24 V
DC
2 A
24 V
DC
max. 10 A
-
500 V (E-bus/field potential)
no
no
yes
yes
1
yes
yes
-
no address or configuration settings
approx. 65 g
0°C ... +55°C
-25°C ... +85°C
95%, no condensation
approx. 15 mm x 100 mm x 70 mm (width aligned: 12 mm)
on 35 mm mounting rail conforms to EN 60715
conforms to EN 60068-2-6/EN 60068-2-27, see Installation instructions [} 76] for en-
hanced mechanical load capacity
conforms to EN 61000-6-2/EN 61000-6-4
IP 20
variable, see chapter "Mounting of Passive
Terminals [} 83]"
CE
ATEX [} 84]
cULus [} 86]
Description
Supply input + 24 V for the E-Bus
Supply input + 24 V (connected internally with terminal 6 and positive power
contact)
0 V for supply input (connected internally with terminal 7 and negative power
contact)
PE (connected internally with terminal 8)
0 V for supply input E-Bus
Supply input + 24 V (connected internally with terminal 2 and positive power
contact)
0 V for supply input (connected internally with terminal 3 and negative power
contact)
PE (connected internally with terminal 4)
Version: 3.9
EL9410
-
yes, via LED and in the process image
2 bits (diagnosis)
variable
EL9xxx