Chapter 1 General Description
STATUS LED 1, 2 pattern
STATUS LED 1
STATUS LED 2
Off
Blinking (amber)
4.5.3
Global HDD LED 1, 2 (1-
Global HDD LED indicates the status of HDDs and optical disk drive.
Global HDD1, 2 LED pattern
Global HDD LED 1
On/blinking (green)
Off
Blinking (green)
Off
4.5.4

Power Capping LED

Power Capping LED indicates enabled/disabled status of Power Capping feature as shown below.
Power Capping LED pattern
On (green)
Blinking (green)
Off
28
Description
A temperature warning was detected.
A voltage warning was detected
One or more hard disk drives are failing
(Only RAID system configuration with 2.5
HDD cage).
SEL area becomes 75% full (768 records)
A charge of internal simple UPS is less than
5%. (In case of internal simple UPS
installed)
-2)
Global HDD LED 2
Off
All
On (amber)
In case that HW RAID is configured with
2.5-inch and 3.5-inch cage.
In case that SW RAID is configured with
2.5 HDD cage.
In case that 3.5-inch HDD cage with
optional RAID controller.
Blinking (amber)
In case that RAID is constituted with
optional RAID controller.
In case that SW RAID is constituted with
2.5 HDD cage.
Off
All
Power Capping feature is enabled.
Power Capping is enabled and power control (capping) is working.
Power Capping feature is disabled.
Note
Power Capping LED seems to be lit or blinking amber when STATUS LED is lit or
blinking amber. The amber STATUS LED indicates a hardware failure. Contact your
sales representative.
Express5800/T110j-S, T110j-S (2nd-Gen) User's Guide
Check the internal fan for dusts. Also check if
the fan unit is properly connected.
Contact your sales representative.
Clear the SEL by Server Configuration Utility,
BMC Management Console or NEC ESMPRO
Manager.
Check the AC cords connection and charge
the internal simple UPS.
Configuration
Accessing to hard disk drive or
optical disk drive.
Hard disk drive is failing.
The LED may be lit few seconds
after power is turned on or reset,
and this is normal behavior.
Rebuilding is in progress
No access and No HDD fault
Description