Emerson Rosemount Wireless ET410 Quick Start Manual page 27

Corrosion transmitter
Hide thumbs Also See for Rosemount Wireless ET410:

Advertisement

April 2023
Figure 4-3: Installation application software, provision tab
5. Cut the cable tie that secures the protective cap to the ET410
sensor and remove the cap from the sensor.
6. Place the sensor on the pipe or vessel in the desired location
and then with someone holding it, proceedto the next section.
4.2 
Checking the waveform quality
Procedure
1. Click the Installation tab in the installation application
software.
2. Click the Start button and wait for an ultrasonic waveform to
download from the sensor.
Note
Waveforms are automatically downloaded every 10 seconds.
When a new waveform arrives, the lines briefly become
thicker.
3. Check the quality of the waveform.
Need help?
The first one or two reflections must be well defined above the
noise in the signal. Only one reflection is needed to calculate a
thickness. If the signal is poor, move the sensor to a slightly
different position. Noting that this should not be done by
sliding the device across the measurement surface.
Quick Start Guide
Quick Start Guide
27