Emerson Rosemount Wireless ET410 Quick Start Manual page 17

Corrosion transmitter
Hide thumbs Also See for Rosemount Wireless ET410:

Advertisement

April 2023
2. Double-click the Permasense installation application desktop
icon.
Within approximately 10 seconds, the Permasense installation
tool software should open.
3. Attach the CC21 to the sensor.
4. In the installation application software:
Note
Joining the device to the network could take several minutes.
Figure 3-2: Installation application software, provision tab
3.4 
Sensor installation
Procedure
1. Click the Installation tab in the installation application
software.
2. Click the Start button and wait for an ultrasonic waveform to
download from the sensor.
Quick Start Guide
a) Verify both the sensor ID and the sensor's MAC address,
which are displayed at the top of the screen within 10
seconds.
b) Select the Provision tab.
c) Enter the 5-digit network ID and the 32-hexadecimal
(numbers 0-9 and letters A -F) join key.
d) Click the Provision button.
The system provides confirmation once provisioning is
complete.
e) Ensure the network ID of the gateway is visible in the
Network Discovery panel.
Quick Start Guide
17