Download Print this page

Emerson Rosemount Wireless ET410 Quick Start Manual page 18

Corrosion transmitter
Hide thumbs Also See for Rosemount Wireless ET410:

Advertisement

Quick Start Guide
Note
Waveforms are automatically downloaded every 10 seconds.
When a new waveform arrives, the lines briefly become
thicker.
3. Check the quality of the waveform.
Need help?
The first one or two reflections must be well defined above the
noise in the signal. Only one reflection is needed to calculate
the thickness. If the signal is poor, move the sensor to a
slightly different position. Noting that this should not be done
by sliding the device across the measurement surface.
Figure 3-3: Installation application software, installation
tab
4. Ensure that the measured thickness matches expectations.
5. Ensure the strap tensioner, strap, and sensor(s) are in line
before tightening the work-screws on the strap tensioner.
18
a. Good waveform
b. Poor waveform
April 2023
Emerson.com/Rosemount

Advertisement